Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
2.
Clin Infect Dis ; 77(Suppl 2): S156-S170, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37490746

RESUMO

BACKGROUND: Increasing trends of antimicrobial resistance are observed around the world, driven in part by excessive use of antimicrobials. Limited access to diagnostics, particularly in low- and middle-income countries, contributes to diagnostic uncertainty, which may promote unnecessary antibiotic use. We investigated whether introducing a package of diagnostic tools, clinical algorithm, and training-and-communication messages could safely reduce antibiotic prescribing compared with current standard-of-care for febrile patients presenting to outpatient clinics in Uganda. METHODS: This was an open-label, multicenter, 2-arm randomized controlled trial conducted at 3 public health facilities (Aduku, Nagongera, and Kihihi health center IVs) comparing the proportions of antibiotic prescriptions and clinical outcomes for febrile outpatients aged ≥1 year. The intervention arm included a package of point-of-care tests, a diagnostic and treatment algorithm, and training-and-communication messages. Standard-of-care was provided to patients in the control arm. RESULTS: A total of 2400 patients were enrolled, with 49.5% in the intervention arm. Overall, there was no significant difference in antibiotic prescriptions between the study arms (relative risk [RR]: 1.03; 95% CI: .96-1.11). In the intervention arm, patients with positive malaria test results (313/500 [62.6%] vs 170/473 [35.9%]) had a higher RR of being prescribed antibiotics (1.74; 1.52-2.00), while those with negative malaria results (348/688 [50.6%] vs 376/508 [74.0%]) had a lower RR (.68; .63-.75). There was no significant difference in clinical outcomes. CONCLUSIONS: This study found that a diagnostic intervention for management of febrile outpatients did not achieve the desired impact on antibiotic prescribing at 3 diverse and representative health facility sites in Uganda.


Assuntos
Administração de Caso , Malária , Humanos , Uganda , Pacientes Ambulatoriais , Malária/tratamento farmacológico , Febre/diagnóstico , Febre/tratamento farmacológico , Antibacterianos/uso terapêutico , Instituições de Assistência Ambulatorial , Comunicação , Algoritmos
3.
ESC Heart Fail ; 10(4): 2559-2566, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37312287

RESUMO

AIMS: We aim to assess the theoretical impact of the atrial flow regulator (AFR) on survival in heart failure. METHODS AND RESULTS: The prospective, multicentre, open-label, non-randomised PRELIEVE study (NCT03030274) assessed the safety and efficacy of the Occlutech AFR device in patients with symptomatic heart failure with reduced ejection fraction (HFrEF) (left ventricular ejection fraction (LVEF) ≥ 15% and <40%) or heart failure with preserved ejection fraction (HFpEF) (LVEF ≥40% and <70%) and elevated PCWP (≥15 mmHg at rest or ≥25 mmHg during exercise). In this analysis, after the first 60 patients completed 12 months of follow-up, the theoretical impact of AFR implantation on survival was assessed by comparing the observed mortality rate with the median predicted probability for one-year mortality. Each subject's risk of mortality was predicted from individual baseline data using the Meta-Analysis Global Group in Chronic HF (MAGGIC) prognostic model. A total of 87 patients (46% female, median age 69 years [IQR 62-74]) had undergone successful device implantation for the treatment of HFrEF (53%) and HFpEF (47%). Sixty patients had a complete 12 month follow-up. The median follow-up was 351 days (interquartile range [IQR] 202-370). Six (7%) patients died during follow-up (8.6 deaths per 100 patient-years; 95% confidence interval [CI] 2.7 to 15.5), all of which had HFrEF. The median predicted mortality rate for the overall study population was 12.2 deaths per 100 patient-years (95% CI 10.2 to 14.7). While the observed mortality rate (0 deaths per 100 patient-years) was significantly lower than the median predicted mortality rate (9.3 deaths per 100 patient-years; 95% CI 8.4 to 11.1) in patients with HFpEF (-9.3 deaths per 100 patient-years; 95% CI -11.1 to -8.4), there was no difference in patients with HFrEF (-3.6 deaths per 100 patient-years; 95% CI -9.5 to 3.0). Four deaths were HF-related deaths (5.7 HF-related deaths per 100 patient-years; 95% CI 1.4 to 11.9; 10.8 HF-related deaths per 100 patient-years; 95% CI 2.5 to 23.1 in the HFrEF subgroup). CONCLUSIONS: In patients with HFpEF, the mortality rate following AFR implantation was lower than the predicted mortality rate. Dedicated randomised, controlled trials are needed - and currently ongoing - to investigate whether the AFR improves mortality.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Feminino , Idoso , Masculino , Volume Sistólico , Função Ventricular Esquerda , Estudos Prospectivos
4.
Curr Med Res Opin ; 39(6): 803-810, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37211772

RESUMO

OBJECTIVE: Intraoperative arterial hypotension (IOH) is associated with poor patient outcome. This study aims to compare the hemodynamic effects of Cafedrine/Theodrenaline (C/T) and Noradrenaline (NA) for the treatment of hypotension in patients who develop IOH after anesthesia induction. RESEARCH DESIGN AND METHODS: This is a national, randomized, parallel-group, multicenter, and open-label study. Adult patients (≥50 years, ASA-classification III-IV) who undergo elective surgery will be included. When IOH (MAP <70 mmHg) develops, C/T or NA will be given as a bolus injection ("bolus phase", 0-20 min after initial application) and subsequently as continuous infusion ("infusion phase", 21-40 min after initial application) to achieve MAP = 90 mmHg. Hemodynamic data are captured in real time by advanced hemodynamic monitoring. RESULTS: Primary endpoints, i.e. the treatment-related difference in average mean arterial pressure (MAP) during the "infusion phase" and the treatment-related difference in average cardiac index during the "bolus phase" are assessed (fixed-sequence method). Non-inferiority of C/T compared to NA in achieving 90 mmHg (MAP) when applied as continuous infusion is hypothesized. In addition, superiority of C/T over NA, applied as bolus injection, in increasing cardiac index is postulated. It is estimated that 172 patients are required to establish statistical significance with a power of 90%. After adjusting for ineligibility and dropout rate, 220 patients will be screened. CONCLUSION: This clinical trial will yield evidence for marketing authorization of C/T applied as continuous infusion. Additionally, the effects of C/T compared to NA on cardiac index will be assessed. First results of the "HERO"-study are expected in 2024. DRKS identifier: DRKS00028589. EudraCT identifier: 2021-001954-76.


Assuntos
Hipotensão , Adulto , Humanos , Hipotensão/tratamento farmacológico , Norepinefrina/efeitos adversos , Hemodinâmica , Anestesia Geral/efeitos adversos
5.
PLoS One ; 18(1): e0267516, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36662693

RESUMO

Accurate and precise point-of-care (POC) testing for C-reactive protein (CRP) can help support healthcare providers in the clinical management of patients. Here, we compared the analytical performance of 17 commercially available POC CRP tests to enable more decentralized use of the tool. The following CRP tests were evaluated. Eight quantitative tests: QuikRead go (Aidian), INCLIX (Sugentech), Spinit (Biosurfit), LS4000 (Lansionbio), GS 1200 (Gensure Biotech), Standard F200 (SD Biosensor), Epithod 616 (DxGen), IFP-3000 (Xincheng Biological); and nine semi-quantitative tests: Actim CRP (ACTIM), NADAL Dipstick (nal von minden), NADAL cassette (nal von minden), ALLTEST Dipstick (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10-40-80 (Hangzhou Alltest Biotech), ALLTEST Cassette cut-off 10-30 (Hangzhou Alltest Biotech), Biotest (Hangzhou Biotest Biotech), BTNX Quad Line (BTNX), BTNX Tri Line (BTNX). Stored samples (n = 660) had previously been tested for CRP using Cobas 8000 Modular analyzer (Roche Diagnostics International AG, Rotkreuz, Switzerland (reference standards). CRP values represented the clinically relevant range (10-100 mg/L) and were grouped into four categories (<10 mg/L, 10-40 mg/L or 10-30 mg/L, 40-80 mg/L or 30-80 mg/L, and > 80mg/L) for majority of the semi-quantitative tests. Among the eight quantitative POC tests evaluated, QuikRead go and Spinit exhibited better agreement with the reference method, showing slopes of 0.963 and 0.921, respectively. Semi-quantitative tests with the four categories showed a poor percentage agreement for the intermediate categories and higher percentage agreement for the lower and upper limit categories. Analytical performance varied considerably for the semi-quantitative tests, especially among the different categories of CRP values. Our findings suggest that quantitative tests might represent the best choice for a variety of use cases, as they can be used across a broad range of CRP categories.


Assuntos
Proteína C-Reativa , Testes Imediatos , Humanos , Programas Governamentais , Pessoal de Saúde , Assistência Médica , Sistemas Automatizados de Assistência Junto ao Leito
6.
Microbiol Spectr ; 10(5): e0122922, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36066256

RESUMO

Access to reverse transcription-PCR (RT-PCR) testing, the gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection, is limited throughout the world, due to restricted resources, available infrastructure, and high costs. Antigen-detecting rapid diagnostic tests (Ag-RDTs) overcome some of these barriers, but independent clinical validations in settings of intended use are scarce. To inform the World Health Organization's (WHO) emergency use listing (EUL) procedure and ensure affordable, high-quality Ag-RDTs, we assessed the performance and ease of use of the SureStatus for SARS-CoV-2. For this prospective, multicenter diagnostic accuracy study, we recruited unvaccinated participants with presumed SARS-CoV-2 infection in India and Germany from December 2020 to March 2021, when the Alpha (B.1.1.7) variant was predominantly circulating. Paired swabs were performed for (i) routine clinical RT-PCR testing (sampling was either nasopharyngeal [NP] or combined NP and oropharyngeal [NP/OP]) and (ii) Ag-RDT (sampling was NP). Performance of the Ag-RDT was compared to RT-PCR overall and by predefined subgroups, e.g., cycle threshold (CT) value, symptoms, and days from symptom onset. To understand the usability, a system usability scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. A total of 1,119 participants were included in the analysis, of whom 205 (18.3%) were RT-PCR positive. SureStatus detected 169 out of 205 RT-PCR-positive participants, reporting a sensitivity of 82.4% (95% confidence interval [CI]: 76.6% to 87.1%) and a specificity of 98.5% (95% CI: 97.4% to 99.1%). In the first 7 days post-symptom onset, the sensitivity was 90.7% (95% CI: 83.5% to 94.9%), when CT values were low and viral loads were high. The test was characterized as easy to use (SUS, 85/100) and considered suitable for point-of-care settings, although quality concerns were raised due to visibly contaminated packaging of swabs included in the test kits. The SureStatus diagnostic test can be considered a reliable test during the first week of SARS-CoV-2 infection, with high sensitivity in combination with excellent usability. IMPORTANCE Our manufacturer-independent, prospective diagnostic accuracy study assessed clinical performance in participants presumed to have a SARS-CoV-2 infection at three study sites in two countries. We assessed the accuracy overall and in predefined subgroups (CT values and symptom duration). SureStatus performed with high sensitivity. Its sensitivity was particularly high in the first 3 days after symptom onset and when CT values were low (i.e., the viral load was high). The system usability and ease-of-use assessment complements the accuracy assessment of the test and highlights critical factors to facilitate the widespread use of SureStatus in point-of-care settings. The high sensitivity demonstrated by the evaluated Ag-RDT within the first days of symptoms, when most transmission occurs, supports the role of Ag-RDTs for public health-relevant screening. Evidence from this study was used to inform the World Health Organization Emergency Use Listing procedure.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Testes Diagnósticos de Rotina , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Organização Mundial da Saúde
7.
Atmos Environ (1994) ; 290: 119372, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36092472

RESUMO

In March 2020, the World Health Organization declared a pandemic due to the rapid and worldwide spread of the SARS-CoV-2 virus. To prevent spread of the infection social contact restrictions were enacted worldwide, which suggest a significant effect on the anthropogenic emission of gaseous and particulate pollutants in urban areas. To account for the influence of meteorological conditions on airborne pollutant concentrations, we used a Random Forest machine learning technique for predicting business as usual (BAU) pollutant concentrations of NO2 and PM10 at five observation sites in the city of Berlin, Germany, during the 2020 COVID-19 lockdown periods. The predictor variables were based on meteorological and traffic data from the period of 2017-2019. The differences between BAU and observed concentrations were used to quantify lockdown-related effects on average pollutant concentrations as well as spatial variation between individual observation sites. The comparison between predicted and observed concentrations documented good overall model performance for different evaluation periods, but better performance for NO2 (R2 = 0.72) than PM10 concentrations (R2 = 0.35). The average decrease of NO2 was 21.9% in the spring lockdown and 22.3% in the winter lockdown in 2020. PM10 concentrations showed a smaller decrease, with an average of 12.8% in the spring as well as the winter lockdown. The model results were found sensitive to depict local variation of pollutant reductions at the different sites that were mainly related to locally varying modifications in traffic intensity.

8.
Sci Total Environ ; 838(Pt 4): 156516, 2022 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-35679943

RESUMO

The worldwide restrictions of social contacts that were implemented in spring 2020 to slow down infection rates of the SARS-CoV-2 virus resulted in significant modifications in mobility behaviour of urban residents. We used three-year eddy covariance measurements of size-resolved particle number fluxes from an urban site in Berlin to estimate the effects of reduced traffic intensity on particle fluxes. Similar observations of urban surface-atmosphere exchange of size-resolved particles that focus on COVID-19 lockdown-related effects are not available, yet. Although the site remained a net emission source for ultrafine particles (UFP, Dp < 100 nm), the median upward flux of ultrafine particles (FUFP) decreased from 8.78 × 107 m-2 s-1 in the reference period to 5.44 × 107 m-2 s-1 during the lockdown. This was equivalent to a relative reduction of -38 % for median FUFP, which was similar to -35 % decrease of road traffic intensity in the flux source area during that period. The size-resolved analysis demonstrated that, on average, net deposition of UFP occurred only during night when particle emission source strength by traffic was at its minimum, whereas accumulation mode particles (100 nm < Dp < 200 nm) showed net deposition also during daytime. The results indicate the benefits of traffic reductions as a mitigation strategy to reduce UFP emissions to the urban atmosphere.


Assuntos
Poluentes Atmosféricos , COVID-19 , Poluentes Atmosféricos/análise , Atmosfera , Controle de Doenças Transmissíveis , Monitoramento Ambiental/métodos , Humanos , Tamanho da Partícula , Material Particulado/análise , SARS-CoV-2 , Emissões de Veículos/análise
10.
EBioMedicine ; 75: 103774, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34959134

RESUMO

BACKGROUND: Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. METHODS: Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. FINDINGS: 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log10SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. INTERPRETATION: Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. FUNDING: Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité - Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19 , COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
11.
Crit Care Explor ; 3(11): e0577, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34806021

RESUMO

Anaphylatoxin C5a, a proinflammatory complement split product, plays a central role in mediating organ dysfunction. OBJECTIVES: This phase II clinical trial was conducted to study safety, tolerability, pharmacokinetics, and pharmacodynamics of vilobelimab, a recombinant monoclonal antibody against C5a, in patients with severe sepsis or septic shock. DESIGN: Multicenter, randomized, and placebo-controlled study. SETTING AND PARTICIPANTS: Eleven multidisciplinary ICUs across Germany. Adult patients with severe sepsis or septic shock and with early onset of infection-associated organ dysfunction. MAIN OUTCOMES AND MEASURES: Patients were randomly assigned in a ratio of 2:1 to three subsequent dosing cohorts for IV vilobelimab or placebo receiving either 2 × 2 mg/kg (0 and 12 hr), 2 × 4 mg/kg (0 and 24 hr), and 3 × 4 mg/kg (0, 24, and 72 hr). Co-primary endpoints were pharmacodynamics (assessed by C5a concentrations), pharmacokinetics (assessed by vilobelimab concentrations), and safety of vilobelimab. Preliminary efficacy was evaluated by secondary objectives. RESULTS: Seventy-two patients were randomized (16 patients for each vilobelimab dosing cohort and eight patients for each placebo dosing cohort). Vilobelimab application was associated with dosing dependent decrease in C5a compared with baseline (p < 0.001). Duration of C5a decrease increased with more frequent dosing. Membrane attack complex lysis capacity measured by 50% hemolytic complement was not affected. Vilobelimab was well tolerated with similar safety findings in all dose cohorts. No vilobelimab-specific adverse events emerged. For vilobelimab-treated patients, investigators attributed less treatment-emergent adverse events as related compared with placebo. Dosing cohorts 2 and 3 had the highest ICU-free and ventilator-free days. There was no difference in mortality, vasopressor-free days, or renal replacement therapy-free days between the groups. CONCLUSIONS AND RELEVANCE: Administration of vilobelimab in patients with severe sepsis and septic shock selectively neutralizes C5a in a dose-dependent manner without blocking formation of the membrane attack complex and without resulting in detected safety issues. The data warrant further investigation of C5a inhibition in sepsis.

12.
Eur J Anaesthesiol ; 38(10): 1067-1076, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33625060

RESUMO

BACKGROUND: In Germany, hypotension induced by spinal anaesthesia is commonly treated with a combination of cafedrine hydrochloride (C, 200 mg) and theodrenaline hydrochloride (T, 10 mg) in 2 ml. We compared the effectiveness of C/T with ephedrine. OBJECTIVES: The primary objectives were to assess the speed of onset and the ability to restore blood pressure without an increase in heart rate. Secondary objectives were to evaluate maternal/foetal outcomes and the number of required additional boluses or other additional measures. DESIGN: HYPOTENS was a national, multicentre, prospective, open-label, two-armed, noninterventional study comparing C/T with ephedrine in two prospectively defined cohorts. This study relates to the cohort of patients receiving spinal anaesthesia for caesarean section. SETTING: German hospitals using either C/T or ephedrine in their routine clinical practice. PATIENTS: Women aged at least 18 years receiving spinal anaesthesia for caesarean section. INTERVENTIONS: Bolus administration of C/T or ephedrine at the discretion of the attending anaesthesiologist. MAIN OUTCOME MEASURES: Endpoints within 15 min after initial administration of C/T or ephedrine were area under the curve between the observed SBP and the minimum target SBP; and incidence of newly occurring heart rate of at least 100 beats min-1. RESULTS: Although effective blood pressure stabilisation was achieved with both treatments, this effect was faster and more pronounced with C/T (P < 0.0001). The incidence of tachycardia and changes in heart rate were higher with ephedrine (P < 0.01). Fewer additional boluses (P < 0.01) were required with C/T. Although favourable neonatal outcomes were reported in both groups, base deficit and lactate values were greater with ephedrine (P < 0.01). Physician satisfaction was higher with C/T. CONCLUSIONS: After C/T, tachycardia was not a problem, providing an advantage over ephedrine. Fewer additional boluses were required with C/T, suggesting greater effectiveness. An increased base deficit with ephedrine suggests reduced oxygen supply or increased demands in foetal circulation. TRIALS REGISTRATION: Clinicaltrials.gov: NCT02893241, German Clinical Trials Register: DRKS00010740.


Assuntos
Anestesia Obstétrica , Raquianestesia , Hipotensão Controlada , Hipotensão , Adolescente , Adulto , Anestesia Obstétrica/efeitos adversos , Raquianestesia/efeitos adversos , Cesárea , Efedrina , Feminino , Humanos , Hipotensão/induzido quimicamente , Hipotensão/diagnóstico , Hipotensão/tratamento farmacológico , Recém-Nascido , Norepinefrina/análogos & derivados , Fenilpropanolamina/análogos & derivados , Gravidez , Estudos Prospectivos , Teofilina/análogos & derivados , Vasoconstritores/efeitos adversos
13.
PLoS One ; 15(5): e0233442, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32421745

RESUMO

The Prostate Specific Antigen (PSA) test suffers from low specificity for the diagnosis of Prostate Cancer (PCa). We originally discovered two cancer-related proteins thrombospondin-1 (THBS1) and cathepsin D (CTSD) using a mass-spectrometry-based proteomics approach. The two serum proteins were shown to improve the diagnosis of high-grade PCa. Thus, we developed quantitative ELISAs for the determination of their concentration in human serum. Here we report their analytical performance in terms of limit of detection, specificity, precision, linearity and interferences, which were determined based on CLSI guidelines. Further, we investigated the influence of pre-analytical factors on concentration measurements. For this, blood from 4-6 donors was collected in different tubes and stored at room temperature for different times prior to centrifugation at different centrifugal forces and temperatures. Stability of THBS1 and CTSD under different storage temperatures was also evaluated. Our results show that the assays are specific, linear and sensitive enough to allow measurement of clinical samples. Precision in terms of repeatability and total within-laboratory coefficient of variation (CV) are 5.5% and 8.1% for THBS1 and 4.3% and 7.2% for CTSD, respectively. Relative laboratory-to-laboratory differences were -6.3% for THBS1 and -3% for CTSD. Both THBS1 and CTSD were stable in serum samples, with 80-120% recoveries of concentrations across donors, sample preparation and storage. In conclusion, the ELISAs as part of the novel commercial in vitro diagnostic test Proclarix are suitable for the use in clinical practice. THBS1 and CTSD can be accurately measured for their intended use independent of the lot and laboratory when conditions consistent with routine practice for PSA sampling and storage are used.


Assuntos
Catepsina D/sangue , Neoplasias da Próstata/diagnóstico , Trombospondina 1/sangue , Coleta de Amostras Sanguíneas/métodos , Ensaio de Imunoadsorção Enzimática , Humanos , Masculino , Variações Dependentes do Observador , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Estabilidade Proteica , Proteômica/métodos , Reprodutibilidade dos Testes
14.
BJUI Compass ; 1(1): 15-20, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35474911

RESUMO

Objectives: Selecting patients suspected of having prostate cancer (PCa) for a prostate biopsy remains a challenge. Prostate-specific antigen (PSA)-based testing is hampered by its low specificity that often leads to negative biopsy results or detection of clinically insignificant cancers, especially in the 2-10 ng/mL range. The objective was to evaluate a novel diagnostic test called Proclarix incorporating thrombospondin-1 and cathepsin D alongside total and free PSA as well as age for predicting clinically significant PCa. Patients and methods: The test was developed following a retrospective study design using biobanked samples of 955 men from two reference centres. A multivariate approach was used for model development followed by validation to discriminate significant (grade group ≥2) from insignificant or no cancer at biopsy. The test specificity, positive predictive value (PPV) and negative predictive value (NPV) at a fixed sensitivity of 90% were compared to percent free PSA (%fPSA) alone. The number of avoidable prostate biopsies deemed to be representative of clinical utility was also assessed. Results: In the targeted patient population, the test displayed increased diagnostic accuracy compared to %fPSA alone. Application of the established model on 955 patients at a fixed sensitivity of 90% for significant disease resulted in a specificity of 43%, NPV of 95% and a PPV of 25%. This is in comparison to a specificity of 17%, NPV of 89% and PPV of 19% for %fPSA alone and had the potential to reduce the total number of biopsies needed to identify clinically significant cancer. Further, the test score correlated with significance of cancer assessed on prostate biopsy. Conclusions: The Proclarix test can be used as an aid in the decision-making process if to biopsy men in this challenging patient population. The use of the test could reduce the number of biopsies performed avoiding invasive procedures, anxiety, discomfort, pain and complications.

15.
Respiration ; 99(1): 1-8, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31288246

RESUMO

BACKGROUND: Fractional exhaled nitric oxide (FeNO) is a surrogate marker for airway inflammation, supporting the diagnostic pathway and treatment decisions for asthma patients. OBJECTIVES: Aim of this study was to compare the new analyser Vivatmo pro (Bosch, BV) with NIOX VERO (Circassia, CN) and CLD (Ecomedics, EC). METHODS: In 100 asthmatics (median 53 years [range 20-87], 62% female, 86% on inhaled corticosteroids [mean 1,300 µg beclomethasone dipropionate or equivalent], 35% treated with biologics) 2 FeNO measurements per device were performed. Additionally, the success rate to achieve a valid NO value was evaluated. RESULTS: Sixty-eight percent of the patients had FeNO values below 50 ppb. Median NO concentrations were 31 ppb (range 6-194) for BV, 33 ppb (9-164) for CN and 31ppb (7-353) for EC. Bland-Altman plots suggested an agreement within the predefined limits of ±5 ppb for all analysers within the therapeutically relevant range (0-70 ppb). The highest agreement in FeNO levels were between BV and EC with mean differences of -0.26 (95% CI -1.48 to 0.95) vs. 1.52 (95% CI 0.4-2.6) ppb for CN and EC. The results indicate an equivalence of the methods (two-one sided t test-equivalence test: p < 0.0001, ±5 ppb margins). Acceptance of the measurements was high for all devices (97%). The highest success rate to obtain 2 valid NO values without failed attempts was achieved with the BV analyser (73 vs. 62% for the CN analyser and 46% for the EC analyser). CONCLUSIONS: For the range between 0 and 70 ppb, FeNO concentrations measured with all 3 devices were statistically equivalent within predefined acceptance criteria and did not differ in a clinically relevant way.


Assuntos
Asma/metabolismo , Testes Respiratórios/instrumentação , Óxido Nítrico/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/fisiopatologia , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Capacidade Vital , Adulto Jovem
16.
Sci Total Environ ; 703: 134570, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-31753501

RESUMO

Quantification of the exposure of urban residents to ultrafine particle number concentrations (UFP) is challenging due to its high spatial and temporal variability. Hence, statistical models, e.g. generalized additive models (GAM), may be used to estimate time series or spatial characteristics of UFP. The GAM approach allows the representation of non-linear relations of a response variable with explanatory variables without the need to pre-define model functions. Up to now, GAMs were usually fitted to UFP data from a single site or from mobile measurement campaigns with limited temporal coverage. In this study, GAMs were used to determine UFP, accumulation mode particle (ACC) and total number concentration (TNC) at five urban sites in the cities of Leipzig and Dresden, Germany for the period 2011-2013. As explanatory variables, reanalysis data sets of meteorological quantities, urban geometry and traffic volume data were evaluated. Variables causing concurvity, which is the equivalent to collinearity in non-linear model approaches, were neglected to guarantee the interpretability of the final models. The models were then validated in a ten-fold cross-validation approach. The final models contained smooth functions for the building surface fraction, planetary boundary layer height, traffic volume, air temperature, wind direction, atmospheric pressure, relative humidity, global radiation and precipitation. Adjusted coefficients of determination (R2adj.) for the final models were R2adj. = 0.44 for UFP, R2adj. = 0.51 for ACC and R2adj. = 0.48 for TNC. Coefficients of determination of the cross-validation were in a similar range (0.44 for UFP, 0.51 for ACC, 0.49 for TNC). Finally, our study shows that GAMs are able to represent important processes that contribute to the particle number concentration from the smooth functions, i.e. emission, dilution, nucleation, deposition and long-range transport.

17.
BMC Cancer ; 19(1): 694, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307414

RESUMO

BACKGROUND: Current evidence suggests that patients with Luminal A early breast cancer can skip chemotherapy or extended endocrine therapy, but immunohistochemistry-based biomarker analysis for St Gallen subtyping may not be reproducible. We asked whether RT-qPCR can be used instead to address this clinical question. METHODS: RNA was extracted from tumor material derived from ER+/HER2- patients receiving adjuvant endocrine treatment for low-risk cancers and was semi-quantified by RT-qPCR with the MammaTyper®. St Gallen subtypes were based on the mRNA expression of ERBB2/HER2, ESR1/ER, PGR/PR and MKI67/Ki67 after dichotomizing at predefined cut-offs. Differences in distant disease-free survival (DDFS) were assessed by Kaplan Meier analysis and Cox regression. RESULTS: With a median follow up of 7.8 years, there were ten events in the group of 195 Luminal A-like tumors (5.1%) and 18 events in the remaining 127 tumors (14.1%), consisting mostly of Luminal B-like cases (N = 119). Luminal A-like had significantly better DDFS over the entire follow-up period (HR 0.35, 95% CIs 0.16-0.76, p = 0.0078) with a trend towards reduced probability of recurrences also in the late phase (> 5 years) (HR 0.20, p = 0.052). The survival advantage spanning the entire follow-up period persisted in the pN0 or pN0-N1 subgroups or after correcting for clinicopathological parameters. MKI67 alone significantly predicted for worse DDFS (HR 2.62, 95% CIs 1.24-5.56, p = 0.0088). CONCLUSIONS: St Gallen Luminal A-like tumors identified by RT-qPCR display markedly low rates of distant recurrence at ten years follow-up. Patients with such tumors could be spared chemotherapy due to the obviously unfavourable benefit/toxicity ratio.


Assuntos
Antineoplásicos Hormonais/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Recidiva Local de Neoplasia , Receptor ErbB-2/genética , Receptores de Estrogênio/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/genética , Neoplasias da Mama/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , Expressão Gênica , Humanos , Estimativa de Kaplan-Meier , Antígeno Ki-67/genética , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos
18.
Complement Ther Med ; 45: 136-141, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31331550

RESUMO

OBJECTIVES: Infantile colic is a common benign disease occurring in early infancy that may have a great impact on family life. In the present study, the effectiveness and safety of the complex homeopathic medicine Enterokind was compared with Simethicone for treating infantile colic. DESIGN AND SETTING: Current data were drawn from a prospective, multicenter, randomized, open-label, controlled clinical trial that was conducted in 2009 in 3 Russian outpatient clinics. Children received either Enterokind (Chamomilla D6, Cina D6, Colocynthis D6, Lac defloratum D6 and Magnesium chloratum D6) or Simethicone. Data from infants ≤ 6 months with infantile colic are presented here. MAIN OUTCOME MEASURES: The main outcomes assessments were the change of total complaints score (maximum 17 points) and total objective symptoms score (maximum 22 points) after 10 days of treatment. RESULTS: Data from 125 infants ≤ 6 months with infantile colic were analyzed. The differences in total complaints and objective symptoms scores between baseline and day 10, estimated from the ANCOVA model, were found to be highly significant (p < 0.0001; ITT) in favor of Enterokind, both for complaints (Δ=-2.38; 95% confidence interval (CI): [-2.87; -1.89]) and for objective symptoms (Δ=-2.07; 95% CI: [-2.65; -1.49]). 1 adverse event (AE), vomiting, occurred under Enterokind and was rated to be unlikely related to it; 4 AEs occurred under Simethicone. All AEs were non-serious. CONCLUSIONS: The current study indicates that Enterokind is an effective and safe homeopathic treatment for functional intestinal colic in infants ≤ 6 months.


Assuntos
Cólica/tratamento farmacológico , Criança , Pré-Escolar , Ensaios Clínicos como Assunto , Homeopatia/métodos , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos , Simeticone/uso terapêutico
19.
Mol Ecol ; 26(22): 6238-6252, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28950417

RESUMO

Human leukocyte antigen (HLA) genes play a key role in the immune response to infectious diseases, some of which are highly prevalent in specific environments, like malaria in sub-Saharan Africa. Former case-control studies showed that one particular HLA-B allele, B*53, was associated with malaria protection in Gambia, but this hypothesis was not tested so far within a population genetics framework. In this study, our objective was to assess whether pathogen-driven selection associated with malaria contributed to shape the HLA-B genetic landscape of Africa. To that aim, we first typed the HLA-A and -B loci in 484 individuals from 11 populations living in different environments across the Sahel, and we analysed these data together with those available for 29 other populations using several approaches including linear modelling on various genetic, geographic and environmental parameters. In addition to relevant signatures of populations' demography and migrations history in the genetic differentiation patterns of both HLA-A and -B loci, we found that the frequencies of three HLA alleles, B*53, B*78 and A*74, were significantly associated with Plasmodium falciparum malaria prevalence, suggesting their increase through pathogen-driven selection in malaria-endemic environments. The two HLA-B alleles were further identified, by high-throughput sequencing, as B*53:01:01 (in putative linkage disequilibrium with one HLA-C allele, C*04:01:01:01) and B*78:01 in all but one individuals tested, making them appropriate candidates to malaria protection. These results highlight the role of environmental factors in the evolution of the HLA polymorphism and open key perspectives for functional studies focusing on HLA peptide-binding properties.


Assuntos
Resistência à Doença/genética , Genética Populacional , Antígenos HLA-B/genética , Malária Falciparum/genética , África Subsaariana , Alelos , Humanos , Desequilíbrio de Ligação
20.
Complement Ther Clin Pract ; 28: 181-191, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28779928

RESUMO

OBJECTIVE: To investigate the effectiveness and safety of the homeopathic product SilAtro-5-90 in recurrent tonsillitis. METHODS: In this international, pragmatic, controlled clinical trial, 256 patients (6-60 years) with moderate recurrent tonsillitis were randomized to receive either SilAtro-5-90 in addition to standard symptomatic treatment, or to receive standard treatment only. The primary outcome was the mean time period between consecutive acute throat infections (ATI) within 1 year (analyzed via repeated events analysis). RESULTS: During the evaluation year, the risk of getting an ATI was significantly lower (hazard ratio: 0.45, proportional means model, p = 0.0002, ITT) with SilAtro-5-90 compared to control. Tonsillitis-specific symptoms were significantly reduced (p < 0.0001, ITT) and the need of antibiotics to treat acute throat infections (p = 0.0008; ITT) decreased. 3 non-serious adverse drug reactions were reported for SilAtro-5-90. CONCLUSIONS: An integrative treatment approach where SilAtro-5-90 is given alongside mainstream symptomatic treatment may bring therapeutic benefit to patients suffering from recurrent tonsillitis. TRIAL REGISTRATION: ISRCTN registry: Registration number ISRCTN19016626, registered 23 January 2013.


Assuntos
Homeopatia , Materia Medica/uso terapêutico , Tonsilite/tratamento farmacológico , Adolescente , Adulto , Antibacterianos/uso terapêutico , Criança , Comunicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Faringite , Recidiva , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA